HALO® C8 HPLC Columns from Advanced Materials Technology

HALO® C8 is a high-speed, high-performance liquid chromatography column based on a new Fused-Core® particle design. The Fused-Core® particle provides a thin porous shell of high-purity silica surrounding a solid silica core. This particle design exhibits very high column efficiency. The densely bonded, extensively endcapped dimethyloctyl stationary phase of HALO® C8 provides a stable, reversed-phase packing that can be used for basic, acidic, or neutral compounds.

Available in 3 particle sizes:

  • HALO® 2 µm columns can meet or exceed the performance of most non-core sub-2 µm columns at pressures one-third to one-half the back pressure under the same conditions
  • HALO® 2.7 µm columns can meet or exceed the performance of most non-core sub-2 µm columns at pressures one-third to one-half the back pressure under the same conditions
  • HALO® 5 µm columns match the performance of totally porous 3 µm columns at roughly half the back pressure under the same conditions

HALO® C8 HPLC columns from Advanced Materials Technology are based on Fused-Core® technology for high efficiency separations with low backpressures. The C8 phase is suited for a broad range of reversed phase applications and provides less hydrophobic retention compared to C18 phases. Available with 2 µm, 2.7 µm, and 5 µm for use with UHPLC or conventional HPLC equipment.

Part Number Product Description Price Qty
product image

Features

  • C8 stationary phase meets USP L7 classification
  • Ideal for broad range of analytes
  • Typical applications include cholesterol lowering pharmaceutical (statin) compounds, flavonoids, and lipid analysis of algal oil
  • Less retentive than C18
  • Better for ion-pair applications than C18
  • Available with 2 µm, 2.7 µm, and 5 µm superficially porous particles

Specifications

  HALO® C8
Bonded Phase C8
Particle Type Fused-Core®
Particle Size 2 µm, 2.7 µm, 5 µm
Pore Size 90 Å
Endcapped Yes
Low pH/Temperature Limit 2/60°C
High pH/Temperature Limit 9/40°C
Pressure Limit 2 µm - 1000 bar
2.7 µm and 5 µm - 600 bar
Hardware Stainless Steel
USP Designation L7

Literature

A better path to separations with Fused-Core®
Pioneering Fused-Core® Technology since 2005 - a commitment to innovation, quality and experience
How to take advantage of superficially porous particles for method improvements
Guidebook on reversed phase chemistries and utilizing selectivity for HPLC separations
HALO® guard columns provide optimum protection for your HALO® HPLC and UHPLC column without sacrificing column efficiency