Gas Clean Purification System from Agilent

Gas Clean Filter Supplies from Agilent

The Agilent Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime. Inserting a Gas Clean Filter System in the gas line immediately before the instrument inlet greatly reduces the level of impurities, thus improving trace analysis. Contaminants entering your GC column will also be reduced, which is critical for high temperature analysis and essential for longer column lifetime.

Replacing the filters when they have reached absorption capacity ensures maximum protection of your GC columns and analytical hardware. The sensitive indicators change color, alerting you that the filter needs to be replaced.

A Gas Clean Filter System allows you to use 99.996% (4.6) pure helium instead of the more expensive 99.999% (5.0) or 99.9999% (6.0) grade, while still yielding high quality analytical results. The expected cost savings are 30%.

The Agilent Gas Clean Filter system ensures superior gas purity by removing contaminants such as moisture, oxygen, hydrocarbons, and carbon dioxide. Installing a filter in the gas line before the instrument inlet significantly reduces impurities, enhancing trace analysis and improving the efficiency and accuracy of your GC system. By preventing contamination, these filters help extend column life, maintain sensitivity, and minimise instrument downtime.

Beyond optimising GC performance, the Agilent Gas Purification system enhances operational and cost efficiency. Its tool-free, self-sealing design allows effortless filter replacement, while the integrated Gas Clean Sensor (compatible with 8860/8890 and Intuvo GCs) provides real-time monitoring and alerts when replacement is needed. Agilent Gas Clean Filters offer a cost-effective solution, enabling up to 30% savings by allowing the use of 99.996% (4.6) helium instead of more expensive grades without compromising analytical quality.

Comprehensive filter selection includes:

  • Carrier Gas Filter – Single filter unit with a combination of filters to remove oxygen, moisture, and hydrocarbons from carrier gas for MS applications
  • Moisture Filter – Prevents water contamination to protect analytical integrity
  • Oxygen Filter – Eliminates oxidation risks for extended column life
  • Charcoal Filter - Removes organic compounds and ensures correct performance of FID detectors
  • Carbon Dioxide Filter – Enhances sensitivity and accuracy for TOC analysis and zero-air generators
  • Sulfur Filter – Removes water and sulfur specific compounds like H2S, COS and SO2 from gas streams for the SCD
Part Number Product Description Price Qty
product image

Features

  • Superior Gas Purity – Removes moisture, oxygen, hydrocarbons, and carbon dioxide for cleaner analyses
  • Enhanced GC Performance – Reduces column damage, maintains sensitivity, and minimises instrument downtime
  • Cost-Effective Solution – Saves up to 30% by enabling the use of 99.996% (4.6) helium instead of higher-purity grades
  • Quick & Easy Installation – Tool-free, self-sealing design allows effortless filter replacement
  • Real-Time Monitoring – Integrated Gas Clean Sensor (for 8860/8890 and Intuvo GCs) alerts users when replacement is needed
  • Faster Stabilisation Times – Optimised filtration reduces gas consumption and improves productivity
  • Versatile Applications – Ideal for GC, GC-MS, ICP-OES, ICP-MS, and LC/MS, with high-flow options available
  • Wide Range of Filters – Options available for carrier gas, moisture, oxygen, carbon dioxide, charcoal, and sulphur removal

 

Specifications

  Function Indicator color change Capacity Outlet concentration at operating flow of 1-10 L/min
Oxygen Filter Removes oxygen as well as traces of sulfur and chlorine compounds from carrier gas From green to gray 150 mL oxygen <50 ppb
Moisture Filter/Process Moisture Filter Removes water, oil, and other foreign material from the carrier gas From green to pale brown 7.2 g water <0.1 ppm
Charcoal Filter Removes organic compounds from gas streams No indicator Approximately 7 g, depending on impurities <0.1 ppm
Carrier Gas Filter Single combination filter; removes water, oxygen, and organic compounds Oxygen: from green to gray Moisture: from green to pale brown 100 mL oxygen, 1 g water, organics depending on impurities Oxygen <50 ppb Moisture <0.1 ppm Organics <0.1 ppm
CO2 Filter Removes CO2 from gas stream; to be used in combination with Moisture Filter From white to violet 9 g CO2 <1 ppm
Sulfur Filter Removes water and sulfur specific compounds like H2S, COS and SO2 from gas streams From green to pale brown 5.3 g water. 2-7 g Sulfur compounds, depending on impurities. Moisture < 0.1 ppm
Sulfur < 0.1 ppm

Videos

Literature

Overview of the Gas Clean filter range

Gas Clean filters for chromatography, ICP, and TOC

Instructions for using Agilent's Gas Clean Filters
Your essential resource for supplies