Element Lab Solutions is under new ownership and will trade as Crawford Scientific from 1 May 2026.

Agilent DB-WAX Ultra Inert GC Columns

Gas chromatography (GC) columns with polyethylene glycol (PEG) stationary phases, also known as WAX GC columns, are commonly used for analyzing compounds with polar functional groups. They are well suited for food, flavor, and fragrance applications, as well as industrial chemical analysis in quality control (QC) and method development labs.

DB-WAX Ultra Inert (UI) represents the ultimate performance of PEG stationary phase inertness, providing symmetric peak shape and improved response for challenging polar compounds. All DB-WAX UI columns are individually tested with an Ultra Inert Wax test probe mixture according to the strictest industry QC standards to ensure consistent column-to-column inertness performance for challenging active analytes, such as free fatty acids, alcohols, diols, and aldehydes, with minimal compound adsorption or degradation.

Since it offers the same selectivity as Agilent J&W DB-WAX, upgrading to Ultra Inert performance is easy, with minimal validation required. There is no need to recreate or modify existing compound libraries that are based on DB-WAX selectivity.

DB-WAX Ultra Inert Intuvo columns are also available for use with your Intuvo 9000 GC instrument.

Part Number Product Description Price Qty
product image

Features

  • Improved peakshape for challenging polar compounds with DB-WAX Ultra Inert
  • Reliable column-to-column inertness performance
  • Bonded polyethylene glycol (PEG) selectivity equivalent to DB-WAX
  • Save time since no method revalidation needed
  • High polarity
  • Equivalent to USP G16
  • Excellent performance for acidic compounds, including free fatty acids – no need for FFAP type column
  • Bonded and crosslinked phase is solvent rinseable and tolerates aqueous injections

 

DB-WAX Ultra Inert Intuvo columns are also available for use with your Intuvo 9000 GC instrument.

Specification

DB-WAX Ultra Inert Temperature Specifications

ID 0.18 – 0.32 mm 0.18 – 0.32 mm 0.53 mm
Length 10 – 40 m 20 – 60 m 15 – 60 m
Film 0.18 – 0.25 µm 0.30 – 0.50 µm 0.25 – 1.00 µm
Temperature Limits 20 – 250/260°C 20 – 240/250°C 20 – 230/240°C

 

Literature

Full range of Agilent Technologies GC columns and applications

Detect every peak and minimize degradative buildup in your GC flow path
Optimising your GC flow path for inertness
For best trace level analysis, maintain your inert flow path with Agilent inert flow path components

Full details on the DB-WAX UI column