Shodex SUGAR (Ligand Exchange) HPLC Columns

Shodex SUGAR (Ligand Exchange) are polymeric-based HPLC columns for the analysis of saccharides, sweeteners, and sugar alcohols. They are ideal for use in the routine quality control in food analysis. The range includes:

  • SUGAR SP0810 – ligand exchange column with lead (Pb2+) counter ions for sugar analysis
  • SUGAR SC1011 – ligand exchange column with calcium (Ca2+) counter ions for saccharide analysis
  • SUGAR SC1211 – combination of ligand exchange (Ca2+ counter ion) and HILIC mode for sugar alcohol separations
  • SUGAR KS-800 Series – combination of ligand exchange (Na+ counter ion) and size exclusion modes for saccharide analysis
  • RSpak DC-613 – ligand exchange (Na+ counter ion) and HILIC mode for separation of mono- and oligo-saccharides
  • SUGAR SZ5532 – ligand exchange (Zn2+ counter ion) and HILIC mode for the separation of disaccharides or trisaccharides
Part Number Product Description Price Qty
product image

Features

SUGAR SP0810

  • Separates saccharides by combination of ligand exchange and size exclusion mode
  • Only water is required for the analysis of neutral sugars
  • SP0810 fulfills USP L22 and L34 requirements
     

SUGAR SC1011

  • Separates saccharides by combination of ligand exchange and size exclusion mode
  • Only water is required for the analysis of neutral sugars
  • SC1011 fulfills USP L19 and L22 requirements


EP SC1011-7F and USPpak MN-431 (special size of SUGAR SC1011)

  • Fulfills mannitol analysis requirements of JP, USP, and EP methods
  • Ca2+ modified ligand exchange chromatography column
  • Only water is required for the analysis of neutral sugars
  • Fulfills USP L19 and L22 requirements


SUGAR SC1211

  • Separates elements by combination of ligand exchange and HILIC modes
  • SC1211 is suitable for separating sugar alcohols
  • SC1211 fulfills USP L19 and L22 requirements


SUGAR KS-801 and KS-802

  • Separates mono- and oligo-saccharides by combination of ligand exchange (Na+) and size exclusion mode
  • Only water is required for the analysis of neutral sugars


KS-803 to 804

  • Suitable for separation of polysaccharides by size exclusion mode
  • Can be used in combination with other columns e.g., KS-802 and KS-801
  • Only water is required for the analysis of neutral sugars
  • Fulfill USP L22 and L58 requirements


RSpak DC-613

  • Separates mono- and oligo-saccharides by combination of ligand exchange (Na+) and HILIC mode
  • Water and acetonitrile is used for the analysis
  • DC-613 can analyze sugars without removing sodium salts in the sample


SUGAR SZ5532

  • Column with zinc (Zn2+) counter ions
  • Separates elements by combination of ligand exchange and HILIC modes
  • Recommended for the separation of disaccharides or trisaccharides
  • Fulfills USP L22 requirements

Specifications

  SUGAR SP0810 SUGAR SC1011 SUGAR EP SC1011-7F USPpak MN-431 SUGAR SC1211 SUGAR KS-801 SUGAR KS-802 SUGAR KS-803 SUGAR KS-804 RSpak DC-613 SUGAR SZ5532
Mode Ligand Exchange Ligand Exchange Ligand Exchange Ligand Exchange Ligand Exchange + HILIC Ligand Exchange Ligand Exchange Ligand Exchange Ligand Exchange Ligand Exchange + HILIC Ligand Exchange + HILIC
Functional group Sulfo (Pb2+) Sulfo (Ca2+) Sulfo (Ca2+) Sulfo (Ca2+) Sulfo (Ca2+) Sulfo (Na+) Sulfo (Na+) Sulfo (Na+) Sulfo (Na+) Sulfo (Na+) Sulfo (Zn2+)
Gel material Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer Styrene divinylbenzene copolymer
Particle size 7 µm 6 µm 8 µm 8 µm 6 µm 6 µm 6 µm 6 µm 7 µm 6 µm 6 µm
Exclusion Limit - 1000 1000 1000 - 1000 10,000 50,000 400,000 - -
Housing material Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Usual flow rate 0.5 - 1 mL/min 0.5 mL/min 0.5 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min 0.5 - 1 mL/min
Temperature range ≤95°C 70 - 85 (≤95°C) 70 - 85 (≤95°C) 30 - 85°C 70 - 80 (≤95°C) 20 - 85°C 20 - 85°C 20 - 85°C 20 - 85°C 20 - 85°C ≤80°C
Shipping solvent H2O H2O H2O H2O H2O/ACN (75/25) H2O H2O H2O H2O H2O/ACN (30/70) H2O/ACN (30/70)
USP Designation L22, L34 L19, L22 L19, L22 L19, L22 L19, L22 L22, L58 L22, L58 L22, L58 L22, L58 L22, L58 L22

Literature

Specialist for polymer based HPLC columns