Agilent Ultra 1 & Ultra 2 GC Columns

All pictures shown are for illustration purpose only. Actual product may vary.
Agilent J&W Ultra 1 is a 100% dimethylpolysiloxane, non polar column that resembles HP-1 but has tighter specifications for retention index and capacity factors. The column has an operating temperature range of –60 to 325/350°C.
Agilent J&W Ultra 2 is a (5%-phenyl)-methylpolysiloxane, non polar column that resembles HP-5, but with tighter specifications for retention index and capacity factors. It has an operating temperature range of –60 to 325/350°C.
Ultra 1 and Ultra 2 columns are intended for use with the Sadtler Retention Index Library.
These precision engineered columns are bonded, cross-linked, and solvent rinsable, and are tested to some of the strictest industry QC standards, ensuring confidence in the accuracy and integrity of analytical results.
Features
Ultra 2 GC Columns
- 100% Dimethylpolysiloxane
- Non polar
- Equivalent to HP-1 with tighter specifications for retention index and capacity factors
- Bonded and cross-linked
- Solvent rinsable
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Similar Phases: SPB-1, Rtx-1, BP-1, 007-1(MS) Ultra 2
Ultra 2 GC Columns
- (5%-Phenyl)-methylpolysiloxane
- Non polar
- Equivalent to HP-5 with tighter specifications for retention index and capacity factors
- Bonded and cross-linked
- Solvent rinsable
- Each Agilent J&W GC column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency to provide you utmost confidence in qualitative and quantitative results
- For details about the QC test conditions including the test probe mixture and the resulting chromatogram, please refer to the Agilent J&W GC Column Performance Summary shipped with each GC column
Similar Phases: SPB-5, Rtx-5, BP-5, CB-5, 007-5, 2B-5
Specifications
Ultra 1 Temperature Specifications
ID (mm) | 0.20 - 0.32 mm |
Length (m) | 12 - 50 m |
Film (µm) | 0.11 - 0.52 µm |
Temperature Limits (°C) | -60 - 325/350 °C |
Ultra 2 Temperature Specifications
ID (mm) | 0.20 - 0.32 mm |
Length (m) | 12 - 50 m |
Film (µm) | 0.11 - 0.52 µm |
Temperature Limits (°C) | -60 - 325/350 °C |