Agilent HP-PLOT Al2O3 GC Columns

Agilent J&W HP-PLOT Al2O3 KCl is the least polar alumina phase and is deactivated with KCl. It is the standard column choice for light hydrocarbon analysis, particularly C1 – C8 hydrocarbon isomers. It is excellent for quantitation of dienes, especially propadiene and butadiene from ethylene and propylene streams.

Agilent J&W HP-PLOT Al2O3 S is the middle polarity alumina phase and is deactivated with sodium sulfate. It is the standard column choice for light hydrocarbon analysis, particularly C1 – C8 hydrocarbon isomers. It is excellent for resolving acetylene from butylene and isobutane.

Agilent J&W HP-PLOT Al2O3 M is the most polar alumina phase and is deactivated by a proprietary method. It is a good general use column for light hydrocarbon analysis for C1 – C8 hydrocarbon isomers. It is good for resolving acetylene from butane and propylene from isobutane.

Part Number Product Description Price Qty
product image

Features

HP-PLOT Al2O3 KCl

  • Least polar Alumina phase
  • Aluminum oxide deactivated with KCl
  • Standard column choice for light hydrocarbons analysis - C1 – C8 hydrocarbon isomers
  • Low retention of olefins relative to comparable paraffin
  • Excellent for quantitation of dienes, especially propadiene and butadiene from ethylene and propylene streams
  • Recommended phase for many ASTM methods
  • Preferred KCl deactivated Alumina

Similar Phases: Rt-Alumina PLOT, Alumina PLOT, Al2O3/KCl, AB-PLOT Al2O3 KCl, AT-Alumina


HP-PLOT Al2O3 S

  • Middle range of polarity for Alumina phases
  • Aluminum oxide deactivated with sodium sulfate
  • Excellent general use column for light hydrocarbon analysis – C1 – C8 hydrocarbon isomers
  • Best for resolving acetylene from butane and propylene from isobutane

Similar Phases: Al2O3/Na2SO4, Rt-Alumina PLOT, Alumina PLOT, Rt-Alumina BOND/Na2SO4, MXT-Alumina BOND/Na2SO4, Alumina sulfate PLOT, AT-Alumina


HP-PLOT Al2O3 M

  • Most polar Alumina phase (similar to GS-Alumina)
  • Aluminiun oxide deactivated with proprietary deactivation
  • Good general use column for analysis of C1 – C8 hydrocarbon isomers
  • Excellent for resolving acetylene from butane and propylene from isobutane

Similar Phases: AB-PLOT Al2O3 M, BGB-PLOT Al2O3 M, AT-Alumina


 

A 7 inch cage is the most common GC column format, compatible with Agilent 5890, 6890, 7820, 7890, 8860, and 8890 series GC systems, and all non-Agilent GC systems with a similarly sized oven. The 5 inch cage format is designed for smaller GC ovens e.g. for the Agilent GC 6850.

Specifications

HP-PLOT Al2O3 KCl Temperature Specifications

ID 0.25 – 0.53 mm
Length 30 – 50 m
Film 5 – 15 µm
Temperature Limits -60 – 200°C

 

HP-PLOT Al2O3 S Temperature Specifications

ID 0.53 mm
Length 15 – 50 m
Film 15 µm
Temperature Limits -60 – 200°C

 

HP-PLOT Al2O3 M Temperature Specifications

ID 0.53 mm
Length 30 – 50 m
Film 15 µm
Temperature Limits -60 – 200°C