Agilent DB-5 GC Columns

Agilent J&W DB-5 is a non polar and low bleed phase, and is available in a range of column dimensions. DB-5 is also bonded, cross-linked, and solvent rinsable, and has a high temperature limit. It is a general purpose column, suitable for a wide variety of applications, and equivalent to USP phase G27. The DB-5 column is tested with the tightest industry QC specifications for column bleed, sensitivity, and efficiency. A number of modified phases are available to allow for different uses, including GC/MS and trace level analysis:

DB-5 – high quality, non polar, general purpose columns
DB-5.625 – specially processed to exhibit excellent inertness for EPA semivolatile methods 625, 1625, 8270, and CLP protocols

Part Number Product Description Price Qty
product image

Features

DB-5 GC Columns

  • (5%-phenyl)-methylpolysiloxane
  • Non polar
  • Low bleed
  • High temperature limit
  • Bonded and cross-linked
  • Solvent rinsable
  • Wide range of column dimensions available
  • Wide range of applications
  • Excellent general purpose column
  • Equivalent to USP Phase G27

Similar Phases: SPB-5, Rtx-5, BP-5, OV-5, 007-2(MPS-5), SE-52, SE-54, XTI-5, PTE-5, ZB-5, AT-5, MDN-5, ZB-5


DB-5.625 GC Columns

Agilent J&W DB-5.625 non polar, bonded columns are specially processed for excellent inertness and selectivity as a standard column for EPA semivolatile methods 625, 1625, 8270, and CLP protocols. The DB-5.625 features high temperature limits with excellent thermal stability and low bleed. Special tested to reliably surpass EPA performance criteria for semivolatiles. The columns are inert and neutral for effective use with basic, neutral and acidic compounds, and are also solvent rinsable.

  • Close equivalent to a (5%-Phenyl)-methylpolysiloxane
  • Specially processed to exhibit excellent inertness for EPA Semivolatiles Methods 625, 1625, 8270 and CLP protocols. Pentachlorophenol, 2,4-Dinitrophenol, Carbazole, and N-Nitrosodiphenylamine used to test response factors
  • Surpasses EPA performance criteria for semivolatiles
  • Inert for base, neutral and acidic compounds
  • Low bleed
  • High temperature limit with excellent thermal stability
  • Bonded and cross-linked
  • Solvent rinsable

Similar Phases: XTI-5, Rtx-5, PTE-5, BPX-5

Specification

DB-5 Temperature Specifications

ID (mm)

0.10 mm 0.15 – 0.32 mm 0.45 – 0.53 mm
Length (m) 10 – 20 m 10 – 60 m 10 – 60 m
Film (µm) 0.10 – 0.40 µm 0.10 – 1.50 µm 0.25 – 5.00 µm
Temperature Limits (°C) -60 – 325/350 °C -60 – 300/320 °C (1.20 µm) 
-60 – 325/350 °C
-60 – 260/280 °C (2.65, 3.00, 5.00 µm) 
-60 – 300/320 °C

 

DB-5.625 Temperature Specifications

ID (mm) 0.18 – 0.32 mm
Length (m) 20 – 60 m
Film (µm) 0.18 – 1.00 µm
Temperature Limits (°C) -60 - 325/350 °C

Literature

Full range of Agilent Technologies GC columns and applications